New approaches for data center layouts needed

Traditional methods would require four times the current floor space in ten years

 
 
New approaches for data center layouts needed

The increasing business demands on IT mean that data center managers must plan to increase their organization’s computing and storage capacity at a considerable rate in the coming years, according to Gartner, Inc.

Organizations that plan well can adjust to rapid growth in computing capacity without requiring more data center floor space, cooling, or power and realize a substantial competitive advantage over their rivals.

“The first mistake many data center managers make is to base their estimates on what they already have, extrapolating out future space needs according to historical growth patterns,” says David Cappuccio, research vice president at Gartner. “This seemingly logical approach is based on two flawed assumptions: that the existing floor space is already being used properly and usable space is purely horizontal.”

To ensure maximum efficiency, data center growth and capacity should be viewed in terms of computing capacity per square foot, or per kilowatt, rather than a simple measure of floor space. A fairly typical small data center of 40 server racks at 60% capacity, housing 520 physical servers and growing in computing capacity at 15% each year, would require four times as much floor space in ten years.

“With conventional thinking and the fear of hot spots at the fore, these 40 racks, or 1,200 square feet of floor space, become nearly 5,000 square feet in just ten years, with associated costs,” says Cappuccio. “A data center manager who rethinks his organization’s floor plans, cooling, and server refreshes can house the increased computing capacity in the original floor space, and help meet growing business needs indefinitely. We will witness small data center environments with significant computing growth rates maintaining exactly the same footprint for the next 15 to 20 years.”

In this scenario, Gartner recommends upgrading the existing server base to thinner 1U (one unit) height servers or even sleeveless servers, while increasing rack capacity to 90% on average by using innovative floor-size designs and modern cooling methods, such as rear door heat exchanger cooling (RDHx), to mitigate concerns over hot spots. Implementing an RDHx system can also reduce the overall power consumption of a data center by more than 40%, since high volumes of forced air are no longer required to cool the equipment.

“An initial investment in planning time and technology refresh can pay huge dividends in the mid-to-long term for businesses anticipating a continuous growth in computing capacity needs,” says Cappuccio.

The evolution of cloud computing adoption will also provide relief for growing data center requirements and as the technology becomes more established, an increasing proportion of data center functions will migrate to specialist or hybrid cloud providers. This further increases the likelihood of an organization making use of the same data center space in the future, generating significant cost savings and competitive business advantages.

John Ginovsky

John Ginovsky is a contributing editor of Banking Exchange and editor of the publication’s Tech Exchange e-newsletter. For more than two decades he’s written about the commercial banking industry, specializing in its technological side and how it relates to the actual business of banking. In addition to his weekly blogs—"Making Sense of It All"—he contributes fresh, original stories to each Tech Exchange issue based on personal interviews or exclusive contributed pieces. He previously was senior editor for Community Banker magazine (which merged into ABA Banking Journal) and for ABA Banking Journal and was managing editor and staff reporter for ABA’s Bankers News. Email him at [email protected].